The C.A.P.
MLC-16X represents the latest in large scale lighting control. It is the best
devices for controlling up to 16 lights from one time-clock or controller. ALL
outlets are circuit breaker protected!
You run 80
(MLC-16X) amp power to the MLC, and all of the outlets are controlled by one
120 volt trigger cable. You can plug the trigger cable into a standard 24 hour
timer or lighting controller.
The MLC-16X
features a 120/240 volt style outlets, which allows for running your ballasts
at 120/240 volts without having to change out your ballast power cords. The
MLC-16X contains 4 banks of 4 lights. Dual trigger cables are also available to
split 2 series of 4 lights. Each bank of 4 lights is protected by a 20 amp
circuit breaker.
The MLC-16X’s
are rated for 80 amps @ 120/240 volts. Includes a 5-year manufacturer’s no
hassle warranty. Made in the USA.
Grower’s Tip:
You must
provide over current protection for the MLC-16X using an 80 amp double pole
circuit breaker at the main panel (require a wire size of at least 4 AWG). Make
certain that your ballasts are wired for 240-volt.